RM-S-60

Hydrogen peroxide low temperature plasma sterilization system is hydrogen peroxide (H₂O₂), in low temperature environment through the electromagnetic field of hydrogen peroxide (H₂O₂) to form hydrogen peroxide (H₂O₂) plasma, combined with hydrogen peroxide (H₂O₂) gas and hydrogen peroxide (H₂O₂) plasma for indoor items at low temperature, dry sterilization, and can effectively dissociate residual hydrogen peroxide (H₂O₂).

Features:

number

name

Description of technical parameters

1

Model and weight

RM-S-60

About 233 KG (net weight)

2

Cavity structure and material

Cavity structure is rectangular, cavity material is 304 stainless steel, thickness ≥ 3mm, square structure, longer service life. Glow ionization net is aluminum alloy 5052, thickness ≥ 3mm .

3

 Inner material

Hexahedral PTC silicone plate is heated, fully independent temperature control, good thermal conductivity, uniform temperature, the inner tank is equipped with sterilization temperature double protection, effectively guarantee the sterilization effect and the safety of equipment and personnel.

4

  sterilization room door

Vertical automated drive lifting door, is equipped with anti-pinch design safety system toensure the equipment and personal safety. New cassette plasma with foot sensor door opening and closing function

5

sterilizing agent

A cassette packed in 58% hydrogen peroxide had 12 capsules each with a volume of 5ml.

6

The method of sterilization

Hydrogen peroxide plasma technology: Hydrogen peroxide online purification technology purithe concentration of hydrogen peroxide to more than 93%, with no residual hydrogen peroxide and no impact on the environment.

7

The sterilization speed

Rapid sterilization time 25min; standard sterilization time 35min and enhanced sterilization time 55min

8

The sterilization temperature

50℃±5℃

9

screen size

7 inch high resolution color touch screen

master controller PLC

New program design, display working process parameters, convenient to operate, easy to understand, fully realize the control accuracy, standardization, safety, reliability;

10

microwriter

Print multiple records, record sterilization parameters, physical curve of sterilization process, record clearly, long service life

The sterilization records are kept

Computer printing provides sterilization time, cycle mode, display pressure, sterilization process, merger and sterilization physical graph printing function. The original data can be saved by large capacity storage, with a complete sterilization record of no less than 8000 times, permanent equipment alarm record, printed record can be saved for more than five years, with the function of power off memory.

11

pressure transmitter

Good accuracy, high reliability, and stable output

12

temperature senso

Dachang brand, good stability, small measurement error

13

sterilizing filter

Ultrafine aseptic filtration, filtration level ≤0.22um

14

RF power source

Frequency 19KHz, maximum power 500W

15

electromagnetic valve

High corrosion resistant material, reliable action life

16

Chamber temperature heating power

1800w, no preheat is required

17

vacuum pump

The rotary plate vacuum pump with extremely high vacuum degree and H202 corrosion resistance is adopted, and the evacuation rate reaches 16 cubic meters / hour, and the operating sound is less than 65dB

18

Vacuum pump phase sequence protector

A high vacuum phase sequence protector is provided to prevent the change, resulting in the reversal of vacuum pump and causing equipment failure

19

Oil mist filter

The product has an exhaust oil mist filtration system, which can recover the oil mist, avoid the oil mist into the air, and through the pump suction, the pump oil back to the pump reuse to reduce fuel consumption.

20

alarm system

System automatic detection function, real-time monitoring of the sterilization process, if any abnormal, the system automatic alarm, and display the cause of failure in Chinese;

21

electro-heating standing-temperature cultivator

Temperature: 56℃ Culture time: 48 hours

test method

Biometritoring of Fatobacillus thermophila

22

The generation of the plasma species

Single AC discharge mode, to ensure 100% plasma discharge success

23

The sterilization residue

Non-toxic damage, no residue

24

Impact on the environment

Safety has no impact

25

Impact on the medical staff

The ultraviolet light caused by the plasma is completely shielded, completely isolated from the operator, and is invisible to the naked eye.

26

Safety of the sterilant

Hydrogen peroxide is ionizes by radiofrequency glow to produce water and oxygen with no residue.

27

The consumables are fully equipped

Plasma special indicator card, adhesive tape, packaging bag, sterilizer, biological indicator, biological incubator, etc. shall be uniformly supplied by the manufacturer.

28

Cavity size (allowable deviation ± 1%)

620*350*280mm;

29

Outer box size (allowable deviation ± 5%)

770*660*1400mm;

30

Nail box size(allowable deviation ± 5%)

790*680*1500mm

31

Power supply and power

220v

2.2KVA

32

scope of application

Suitable for resistant to vacuum negative pressure and hydrogen peroxide gas and high temperature sensitive devices, not suitable for powder, oil and cotton devices.

33

The sterilization effect

2m Teflon chamber with lmm inner diameter and lmm stainless steel chamber with 500mm. Meet the sterility requirements after sterilization.